Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Replace chipped edge of step 8/2/2019
A17.1-1996 : Escalators 7.5 - Lighting 806.2 Upper and lower demarcation lights are not working. Repair 8/2/2019
A17.1-1996 : Escalators 8.1 - Machinery space access, lighting, receptacle, and condition 1206.6a Upper level machine space needs to be cleaned out. 8/2/2019
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 802.8 Step demarcations need to be replaced as needed. 8/2/2019
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 802.8 x Step chains have stretched beyond normal. Need to replace. Red tagged. 8/2/2019
A17.1-1996 : Escalators 7.3 - Handrails 802.4 Both handrails are cracked. Need replacement. 11/3/2020
A17.1-1996 : Escalators 7.5 - Lighting 805.7 Replace broken demarcation strip. 11/3/2020