MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
Car directional arrows, missing lens-provide.
|
|
A17.1-1996 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
1206.2a
|
x
|
|
Light needs to work in the pit.
|
7/8/2019
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Repair emergency phone.
|
7/8/2019
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
204.4
|
|
|
There is an 1 1/8" gap between the cop and the car door. Needs to be fixed. Reinspect.
|
7/25/2019
|
conversion
|
conversion
|
n/a
|
|
|
Post Mo State certificate in machine room
|
7/25/2019
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current operating certificate in machine room.
|
7/25/2019
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current operating certificate in machine room.
|
7/25/2019
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone not working.
|
10/30/2019
|
A17.1-1996 : Elevators
|
1.7 - Car door or gate
|
1001.2(a)(7)
|
|
|
The gap between elevator cab and car door are over 3/8" when the door is in the closed position.
|
9/22/2020
|
A17.1-1996 : Elevators
|
3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing
|
1206.2(c)
|
|
|
Clean elevator car top.
|
9/22/2020
|
A17.1-1996 : Elevators
|
3.13 - Windows, projections, recesses, and setbacks
|
1001.2(c)(19)
|
|
|
Toe guard is hitting the landing sill guard in elevator pit.
|
9/22/2020
|