Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (I) - Pits (I)8 Provide a permanent, non-combustible pit sump pump cover.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing This elevator is equipped with an over speed valve that in not sealed. A category 5 test shall be performed on the over speed valve on or before the next annual inspection. The valve shall be sealed and tagged after the category 5 test.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) 9/14/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing, self-locking and shall be operable from the interior space without the use of a key.
MO Minimum : Elevators (H) - Machine Rooms (H)8 All machine room wiring shall be enclosed. Note: The machine room electrical receptacle is open with exposed wiring and shall be enclosed.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall be operational.
MO Minimum : Elevators (H) - Machine Rooms (H)2 Part of the machine room walls are missing and shall be replaced with approved material.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) The machine room lights shall be operational.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. (2nd Notice)
MO Minimum : Elevators (H) - Machine Rooms (H)2 The machine room door shall be self-closing and self-locking and shall be operable from the interior space without the use of a key. (2nd Notice)
MO Minimum : Elevators (H) - Machine Rooms (H)8 All machine room wiring shall be enclosed. The machine room electrical receptacle is open with exposed wiring and shall be enclosed. (2nd Notice)
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) The pit light shall be operational. (2nd Notice)
conversion conversion n/a Post current State Certioficate in machine room 9/14/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 9/14/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The in car emergency telephone shall be operational. 10/7/2020