ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.1
|
|
|
Provide clean down of unit.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.12 - Steps, step chains, and trusses
|
8.11.4.2.12
|
|
|
Observed numerous damaged and broken step demarcation indicators that shall be repaired or replaced as needed.
|
8/10/2020
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
8.11.4.2.1 (Re-Inspection)
|
|
|
Existing upper and lower demarcation lights shall work.
|
8/16/2022
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
|
|
Unit shall have a clean-down performed.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.19 - Maintenance records
|
8.6.1.4
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided. (This item is for notification purposes for future violation in 2022)
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed.
|
8/16/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Certificate
|
|
|
A current MO State operating certificate shall be obtained and displayed.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
6.1.3.4 (Hand rails) (Re-Inspection)
|
x
|
|
Handrails will be free of major cracks and pinch-points. Replace left handrail. - Violation not corrected as of 7/31/24 re-inspection to complete testing.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.5 - Lighting
|
8.6.11.5(i) Demarcation Lighting (Re-Inspect)
|
x
|
|
Upper & lower step demarcation lighting not working.
|
7/19/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.17 - Step/skirt clearances, panels, and performance index
|
8.6.8.3 Step/Skirt Performance Index
|
x
|
|
Performance index testing graphs, including loaded gap, CoF, Index, etc. to be sent to inspector for verification of results. Note: Step indexing machine broke after completion of this testing.
|
7/19/2024
|
Missouri Minimum : Escalators
|
11 CSR 40-5.090 Inspection and Testing
|
(3) Testing Procedures (Re-Inspect)
|
x
|
|
Testing Incomplete: Only performance index testing and handrail condition tested.
|
7/31/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.3 - Handrails
|
6.1.3.4 (Hand rails) (Re-Inspection)
|
x
|
|
Handrails will be free of major cracks and pinch-points. Replace left handrail.
|
7/31/2024
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.5 - Lighting
|
8.6.11.5(i) Demarcation Lighting (Re-Inspect)
|
x
|
|
The demarcation lights shall be operational.
|
9/20/2021
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators
|
7.9 - Steps and upthrust device
|
8.6.8.6.1 Steps with broken treads shall be repaired or replaced
|
x
|
x
|
Replace the broken step tread.
|
9/20/2021
|