Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Emergency light not working. 10/21/2020
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7 Emergency light shall work. 10/21/2020
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Current state operating certificate shall be displayed in the machine room 7/12/2023
conversion conversion conversion - reinspect x Phone in cab does not work. 8/9/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency bell shall work. 8/7/2020
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x OSV in not sealed and must of a category 5 performed within 90 days or less 7/28/2022