A17.1-1996 : Escalators
|
7.15 - Balustrades
|
802.3
|
No
|
No
|
Bottom deck guards are wrong height and distance from handrail.
|
10/10/2019
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
No
|
No
|
Left handrail is cracked, needs to be replaced
|
3/13/2026
|
|
A17.1-2016 : Elevators
|
8.12 - Steps, step chains, and trusses
|
8.6.8.15.12
|
Yes
|
No
|
Observed broken yellow demarc strips, replace.
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.1 Escalator Handrails
|
Yes
|
No
|
Observed crack left handrail. Replace.
|
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
Yes
|
No
|
Provide unit clean down.
|
|
|
A17.1-1996 : Escalators
|
7.3 - Handrails
|
802.4
|
No
|
No
|
Replace right handrail.
|
9/8/2021
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.2 Escalator Step-to-Skirt Clearance
|
Yes
|
No
|
Right step to skirt indexing failed, not within specifications, needs repaired. Re-inspection required
|
3/13/2026
|
|
Missouri Minimum : Escalators
|
(T) - Existing Dumbwaiters, Escalators and Moving Walks
|
8.6.8.13 Escalator Cleaning
|
No
|
No
|
Unit needs clean down
|
3/13/2026
|
|
A17.1-1996 : Escalators
|
8.1 - Machinery space access, lighting, receptacle, and condition
|
1206.6a
|
No
|
No
|
Upper level machine space needs to be cleaned out.
|
10/10/2019
|