Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light went out when the alarm bell is pressed, repair emergency lights
A17.1-1996 : Elevators 2.4 - Machine space 1001.2(b)(4) Auxiliary power lowering unit batteries are dead, replace batteries - Item 2.44 Rule 306.11
A17.1-1996 : Elevators 5.11 Plunger and Cylinder 1206.5b(5) Oil Leakage Collection Oil on pit floor, jack head was not draining into the pit bucket, clean up oil on pit floor
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 211.2-211.8 x on fire service phase 1 recall after arriving at the recall floor the doors automatically close after 60 seconds, they are to remain open 12/13/2019