Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. 6/16/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display a current MO State operating certificate in the machine room. 6/16/2022
conversion conversion n/a Emergency bell is not operational. 2/3/2021
conversion conversion n/a Emergency light does not operate. 2/3/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Scavenger pumps are not permitted to be used as means to return oil to the tank. 6/16/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing The presence of an overspeed valve has been confirmed. The overspeed valve shall be scheduled for the category 5 test required by A17.1 2016 8.6.5.16.5 on or before the next annual due date per MO AHJ. 2/22/2024