Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Red Tag) x x Repair or replace the emergency phone. There is no dial tone 3/9/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room 3/21/2021
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d Re-attach the machine room door closer as it is to be self closing self latching, always locked outside never locked inside. 3/21/2021
A17.1-1996 : Elevators 2.5 - Housekeeping 1001.2(b)(5) Remove all the stored materials and equipment stored in the machine room. This room is an elevator equipment room not a store room 3/21/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room 4/8/2022
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1001.2(b)(7) Have the fire extinguisher re-certified. 4/8/2022
A17.1-1996 : Elevators 2.1 - Access to machine space 101.3d Remove the dead bolt from the machine room door and replace it with a mechanical room lock. It is to be always locked outside never locked inside , self closing and self latching, spring type lock openable without use of a key 3/23/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room. 3/23/2023