Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Emergency light and alarm shall work. 10/31/2018
conversion conversion n/a Pit light shall work. 10/31/2018
conversion conversion n/a It is recommended that a full length door re-opening device (light ray) be installed. 10/31/2018
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 x This unit experienced unaccountable oil loss after the relief valve test. The unit was red-tagged and placed out of service. The source of the oil loss shall be corrected. 2/26/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 8/4/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 8/4/2022
conversion conversion conversion - reinspect x The shut off valve in the pit is under-rated and shall be replaced. 10/31/2018
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The in car emergency light shall be operational. 2/26/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) x The emergency alarm bell shall be operational on auxiliary power. 2/26/2021