Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 2.17 - Drive machine brake 1001.2(b)(15) x x Perform 125% brake test. Did not red tag. Test will be performed upon return to facility. 4/13/2020
A17.1-1996 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 1001.2(e)10 x Provide car safety test, car buffer, counterweight buffer, record slide. Testing incomplete. 4/13/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Test incomplete. Fire service must be tested. 3/19/2021