Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes No The in car emergency lighting shall work. 10/22/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) Yes No The in car emergency telephone shall work. 10/22/2020
MO Minimum : Elevators (M) - Car Safeties and Speed Governors (M)5 Yes Yes The car safeties failed to operate the SOS switch. Unit Red Tagged. 11/10/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Governor pull out and pull thru and 125% brake test have been completed. The remaining items of the category 5 test and the annual inspection still need to be performed. 11/10/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods No No The covers are missing from the hoistway door interlocks on the 2nd and 3rd floors. 7/2/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current state operating certificate. 7/2/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 No No Properly secure the emergency exit as specified by the code. 7/2/2021
MO Minimum : Elevators (I) - Pits (I)1 No No The pit shall be kept dry. Remove fluids from the pit and provide means to prevent accumulation of ground water from entering the pit. 7/2/2021
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) No No The machine room lighting shall work. 7/2/2021
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)3 No No Attach the escape hatch to the car and secure it so that it is only openable from the outside without the use of tools. 7/2/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No There were no keys on-site to test fire service. Keys to activate fire service shall be kept on-site at all times and fire service shall be tested to complete the annual inspection. 7/22/2021
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No The emergency light and alarm shall be tested to complete the annual inspection. 7/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No The alarm bell on the car top is weak and shall be repaired or replaced. 7/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 7/27/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency bell doesn't work. 8/13/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No Fire service operation shall be tested. Keys were not on-site to test fire service. 8/13/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Replace faded Phase 2 fire service signage. 8/19/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No The pit light shall work. 8/19/2024
MO Minimum : Elevators (A) - Hoistways (A)16 No No Replace missing interlock covers (exposed live wiring). 8/19/2024
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Fire service operation shall be tested. No keys on-site to test. 8/5/2025
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Two-way communication device shall work. Appears to dial, no answer. 8/5/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a non-combustible frame with a clear protective vision plate over it. 9/29/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Machine room door shall be self-closing and self-locking. 9/29/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars No No Car top shall be kept free of excess debris, dirt, and lint. 9/29/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Two-way communication device shall work. (2nd Notice) 9/29/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Fire service operation shall be functional. No keys on-site originally. (2nd Notice) 9/29/2025
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) Yes No Fire service operation shall be functional. Maximum 14 days to correct violation or unit to be red tagged. 10/14/2025