Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 2.18 - Traction drive machines 8.11.2.1.2(u) x x Machine drive sheave severely worn. Ropes will not slip traction upon activation of the car safeties. 11/10/2021
A17.1-2016 : Elevators 2.13 - Governor, Overspeed Switch, and Seal 8.11.2.1.2(ff) x x Governor weights compromised by cement dust, and not freely working. 11/10/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate State Operating Certificate not available due to the Violation Compliance Requirement letter not returned after the Reinspection on 11/10/2021. 2/7/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2 Replacement of Suspension Means (Re-Inspection) x One hoist cable has bad spot. Replace set.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Machine room in extreme conditions. Provide means to reduce the amount of cement dust entering the room. 11/10/2021