MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
Machine room in extreme conditions. Provide means to reduce the amount of cement dust entering the room.
|
11/10/2021
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
State Operating Certificate not available due to the Violation Compliance Requirement letter not returned after the Reinspection on 11/10/2021.
|
2/7/2023
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.3.2 Replacement of Suspension Means (Re-Inspection)
|
x
|
|
One hoist cable has bad spot. Replace set.
|
|
A17.1-2016 : Elevators
|
2.13 - Governor, Overspeed Switch, and Seal
|
8.11.2.1.2(ff)
|
x
|
x
|
Governor weights compromised by cement dust, and not freely working.
|
11/10/2021
|
A17.1-2016 : Elevators
|
2.18 - Traction drive machines
|
8.11.2.1.2(u)
|
x
|
x
|
Machine drive sheave severely worn. Ropes will not slip traction upon activation of the car safeties.
|