Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion n/a Left handrail should be replaced due to cracks
A17.1-1996 : Escalators 7.3 - Handrails 802.2 Need to replace right handrail.
A17.1-1996 : Escalators 8.12 - Steps, step chains, and trusses 802.7 Replace all worn step rollers. 8.6.8.7
A17.1-2016 : Elevators 7.19 - Maintenance records 8.6.1.2.1(c) Provide job specific wiring diagrams.
A17.1-2016 : Elevators 7.19 - Maintenance records 8.6.1.2.1(a) Provide maintenance control program documents.
A17.1-1996 : Escalators 7.3 - Handrails 802.4 Replace both handrails. Splitting noted on outboard and inboard sides.
A17.1-1996 : Escalators 7.5 - Lighting 805.7 Replace step demarcation lights.
A17.1-1996 : Escalators 7.3 - Handrails 802.4 Both handrails need to be replaced due to cracks.
A17.1-2016 : Elevators 8.4 - Drive machine and brake 8.6.8.15.4 Reinspection required, brake torque tests not performed.
A17.1-2016 : Elevators 7.3 - Handrails 8.6.8.1 Left handrail needs replaced
A17.1-2016 : Elevators 7.7 - Combplate and comb step impact device 8.6.8.15.18 Walk on plate switches shall be made operable.
A17.1-1996 : Escalators 7.10 - Operating and safety devices 805.3a The stop button buzzer at the top landing is not sounding and shall be repaired.
A17.1-2016 : Elevators 8.4 - Drive machine and brake 8.6.8.15.4 x The brake torque could not be tested on the initially due to the need for a specific tool. Reinspection for the brake torque is required. 10/30/2024
A17.1-2016 : Elevators 8.4 - Drive machine and brake 8.6.8.15.4 x The brake torque could not be tested on the initially due to the need for a specific tool. Reinspection for the brake torque is required. REINSPECT IN 14 DAYS 11/25/2024
A17.1-2016 : Elevators 8.4 - Drive machine and brake 8.6.8.15.4 x x Brake failed torque test. Red-tagged, Re-inspection required 11/27/2024