ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.2 - Stop switches
|
2.26.2.5
|
|
|
Freight elevator stop switch outer pull ring has been broken, switch works, would like to recommend a key switch item.2.26.2.21 would be better suited for this environment.
|
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.30 - Hydraulic Power Unit
|
8.11.3.1.2(m)
|
|
x
|
Pump unit extremely load, control valve bypassing oil in up direction & the relief pressure 50% less than last test.
|
6/17/2019
|
A17.1-2016 : Elevators
|
1.15 - sign and operating device symbols
|
8.6.1.6.7
|
|
|
In case of fire don't use elevator signage needed
|
9/15/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
phone not working
|
5/25/2021
|
A17.1-2016 : Elevators
|
1.6 - Car emergency signal
|
8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Emergency phone not working
|
8/25/2022
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Car Emergency telephone not working.
|
10/12/2018
|