Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone in elevator cab does not work. Repair phone. Rule B11, Missouri Minimum. Rule 8.11.3.1.1(F) A17.1, 2016. Rule 1.6, A17.2, 2014 5/15/2023
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x 2. Phone in elevator cab does not work. Repair phone. Rule B-11, Missouri minimum. Rule 8.11.3.1.1(F) A17.1, 2016. Rule 1.6, A17.2, 2014. Reinspect by 5-13-22(30 days) 5/26/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher is expired, have serviced or replaced
A17.1-2016 : Elevators 5.15.2 Unsealed Overspeed Valve 8.6.5.16.5 (Re-Inspect) x 1. Overspeed valve is not sealed and needs full load test and tripping speed checked. Rule 8.6.5.16.5, A17.1, 2016Reinspect by 7-13-22(90 days) 5/26/2022
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing OSV is not sealed. Perform OSV test on or before next annual inspection date.