Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of current state operating certificate shall be properly displayed in machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room 1/9/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Emergency phone in car does not work, appears to be an issue with the line. Re-inspection required 1/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher in machine room is expired. Replace or have serviced 1/9/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) x OSV is overdue for testing as noted in last inspection. Perform required testing, seal & tag within 90 days. Re-inspection required 1/9/2023
A17.1-1996 : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing Perform OSV test. Tag and seal upon completion. 1/5/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Phone failed to operate 1/9/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Remove all non elevator related wiring from machine room, including coaxial cable & power for tv in adjacent room 1/9/2023
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Remove unused wiring connected to exhaust fan switch in machine room or use power fan in accordance with NFPA 70 1/9/2023
A17.1-1996 : Elevators 2.8 - Pipes, wiring, and ducts 102.1 Wiring for exhaust fan in machine room shall be made permanent, be grounded & be properly enclosed in conduit per NFPA 70 1/9/2023