Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log the monthly fire service test log in the machine room has not been filled out, perform monthly fire service test and fill out test log 10/16/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting elevator cab ceiling has an open egg crate drop ceiling, the light tubes shall be in protective tube covers 2/17/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate the state operating certificate in the machine room is from 2019, a new copy is to be posted in the machine room every year. 2/17/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Install light tube covers on the cab ceiling lights or plastic light tubes 8/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Replace burnt out car top light bulb 2.14.7.1.4 8/8/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x emergency phone did not call out, no dial tone on phone line, repair phone line 9/30/2022
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x the emergency phone was not answered, it calls a number that is not staffed 24 hours a day 7 days a week 8/19/2020