A17.1-2016 : Elevators
|
3.17 - Door and gate equipment
|
8.11.2.1.3(w)
|
Yes
|
No
|
Upper hoistway door hanger safety retainers are defeated/turned down on almost all doors. Shall be corrected. (Previously Cited Violation)
|
|
|
A17.1-2016 : Elevators
|
5.2 - Bottom clearance, runby, and minimum refuge space
|
2.4.2
|
Yes
|
No
|
Counterweight runby, 1.5", does not meet Code Requirements. Shorten cables
|
|
|
A17.1-2016 : Elevators
|
1.16 - Rated load, platform area, and data plate
|
2.16.5
|
No
|
No
|
COP shall have car number displayed, 0.5" lettering.
|
|
|
A17.1-1996 : Elevators
|
3.27 - Crosshead data plate
|
212.2
|
No
|
No
|
Suspension ropes shall have proper data tag(s)
|
|
|
A17.1-2016 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
8.6.4.7 Cleaning of Pits
|
No
|
No
|
Pit shall be kept clean. Remove excess debris
|
|
|
A17.1-1996 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
211.3a(8) Visual and audible signal
|
Yes
|
No
|
Phase I buzzer inoperative.
|
4/23/2021
|
|
A17.1-1996 : Elevators
|
1.6 - Car emergency signal
|
1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
Yes
|
No
|
Emergency phone does not work.
|
4/23/2021
|
|
A17.1-1996 : Elevators
|
2.3 - Lighting and receptacles
|
1001.2(b)(3) Inspection code
|
No
|
No
|
Relamp machine room lighting fixtures above machines.
|
5/12/2021
|
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
No
|
No
|
A current MO state operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vison plate over it.
|
4/2/2025
|