Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Unable to communicate with emergency personnel over phone 11/10/2022
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Unable to communicate with emergency personnel over phone. Re-inspection required 12/5/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Elevator cab phone does not work, needs repaired. Re-inspection required
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher needs to be replaced. 8/15/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Fire extinguisher needs to be serviced. 1/2/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No maintenance records. 1/2/2019
MO Minimum : Elevators (H) - Machine Rooms (H)1 Step going into machine room is hanging. Welds are broken on the step. 8/15/2023
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Covers over machine room lights. 1/2/2019
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Housekeeping needed in machine room. 1/2/2019
MO Minimum : Elevators (H) - Machine Rooms (H)1 Step going to machine room is broken
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Lights in machine room do not work
MO Minimum : Elevators (H) - Machine Rooms (H)1 Step going into machine room is broken
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Lights in machine room do not work
MO Minimum : Elevators (I) - Pits (I)1 Clean trash out of pit. 1/2/2019
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace machine room lighting. 8/15/2023
MO Minimum : Elevators (I) - Pits (I)1 Clean pit area. 8/15/2023
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)1(A) Hoist cable tags needed. 1/2/2019
MO Minimum : Elevators (S) - Fire Service 211.7 Firefighters Operations/Signage Operating instruction signs for Phase I & II fire service are missing, need to install signage
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Unable to communicate with emergency personnel over phone. Re-inspection required 11/21/2024
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Display current certificate in machine room. 8/15/2023
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current operating certificate shall be displayed in the machine room
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A copy of the current state operating certificate shall be displayed in the machine room