Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Machine room light needs to work and be guarded. 10/30/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.5.5.2 Oil Leakage Collection Scavenger pumps that do not record the amount of oil returned to the hydraulic tank in the machine room cannot be installed in the elevator pit. Either install a recordable scavenger pump or limit the amount of oil stored in the elevator pit. 3/22/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Written maintenance control program shall be provided on site for each elevator. 3/22/2021
MO Minimum : Elevators (O) - Existing Hydraulic Elevators (O)4 x During 15 minute standing test, the car dropped 5" with shut off valve closed in machine room. Leak appears to be in the underground piping or the inground hydraulic jack. Red tagged elevator. 3/12/2021