Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates Phase I and Phase II instruction not legible 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.7 Cleaning of Hoistway and Pit Pit needs cleaning 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No records 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts Phase I instruction not legible 8/9/2024
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Rear cab glass broken. 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean top of car 8/9/2024
MO Minimum : Elevators (I) - Pits (I)1 Sump pump not working required to be on a NON GFI 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces Caulk all penetration. 8/9/2024
MO Minimum : Elevators (I) - Pits (I)1 Remove the standing 8" of water from the elevator pit. 8/9/2024
MO Minimum : Elevators (I) - Pits (I)1 Replace the non working sump pump in the pit. 8/9/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace the broken pit light 8/9/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace the electrical equipment in the pit with NEMA 4 rated for wet location per the NEC 358.12(5) also 310.8 damp or wet locations 8/9/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Phone not working 8/23/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light/bell failed 6/21/2023