Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 1.17 - Standby power operation 8.10.2.3.2(l) Yes No Need to test the operation of emergency power with full capacity in the elevator. Emergency power was not tested during the acceptance.
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability No No "ELEVATOR COMMUNICATIONS FAILURE" feature needs to be provided to verify operability of the telephone line.
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.19.15 Emergency Communications Yes No A visual indication on the same panel as the “PHONE” push button shall be provided, that is activated by authorized personnel, to acknowledge that two-way communications link has been established.
A17.1-2016 : Elevators 2.14 - Code data plate 8.7.1.8 Yes No A data plate shall be provided as required by 8.6.1.5. In jurisdictions enforcing NBCC, the data plate required by 8.9.1 shall include the code and edition in effect at the time of alteration and the requirements in Section 8.7 that were applicable to the alteration. 4/23/2026
A17.1-2016 : Elevators 2.30 - Hydraulic Power Unit 8.10.3.3.2(p) Yes No 8.7.3.31.5(c)(8) The elevator identification needs to be labeled on on both doorjambs of every elevator entrance at the designated level, alternate level, level where means necessary for tests is provided, and the driving machine. 4/23/2026
MO Minimum : Elevators (H) - Machine Rooms (H)2 Yes No Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment or come in close proximity of the equipment shall be guarded or guttered. 4/23/2026
A17.1-2016 : Elevators 2.8 - Pipes, wiring, and ducts 3.8 Yes No 8.7.3.8 The hydraulic line cannot be located in front the controller. Then area in front of the controller needs to be clear from the floor to the top of the controller 36" deep and 30" wide. 4/23/2026
A17.1-2016 : Elevators 1.17 - Standby power operation 8.10.3.3.2(l) Yes No Need to test the operation of emergency power. 4/23/2026
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1.1.6 Verification of Telephone Operability Yes No 8.7.3.31.5(c)(7) "ELEVATOR COMMUNICATIONS FAILURE" feature needs to be provided to verify operability of the telephone line. 4/23/2026
A17.1-2016 : Elevators 1.6 - Car emergency signal 8.6.4.19.15 Emergency Communications Yes No 8.7.3.31.5(c)(7)A visual indication on the same panel as the “PHONE” push button shall be provided, that is activated by authorized personnel, to acknowledge that two-way communications link has been established. 4/23/2026