Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 3.4 - Top-of-car Clearance, Refuge Space, & Standard Railing 1206.2(c) No No Clean oil from car top, including car fan and ceiling fixtures. 11/15/2021
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits No No Clean pit. 11/15/2021
A17.1-1996 : Elevators 2.18 - Traction drive machines 1001.2(b)(16) Yes No Drive sheave seals and worm shaft seals are worn and leaking. Repair as needed. 11/15/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency lights and alarm bell do not work. 11/15/2021
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone does not have 2-way communication. 10/13/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)(12) - No No Fireman's light and audible needs to work. 5/13/2020
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Maintenance control program shall include current records of maintenance performed. 10/23/2020
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)(12) Yes Yes Phase 2 is not working, hold does not work, fireman's in car light and buzzer not working. Must be repaired within 30 days, reinspected by October 9th or unit will be red tagged. 10/13/2020
conversion conversion conversion - reinspect Yes No Phase I light and buzzer not working 8/30/2018
conversion conversion conversion - reinspect Yes No Phase Ii does not work 8/30/2018
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Provide existing phone to work, pushing button = nothing. 9/2/2025
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide on-site maintenance control program. 2/11/2021
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide on-site maintenance control records. 11/15/2021
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 1001.2(a)(18) Yes No Repair door detector, currently working off light/bell 110V circuit. When power is removed, it does not work. 11/15/2021
A17.1-1996 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 1001.2(d)(12) Yes Yes Repair firefighters service phase II so that it operates as intended. Hold does not work. Did not red tag unit. Reinspect only. 8/2/2019