Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) Need testing procedures included in the MCP on or before 1/1/22 11/24/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x Emergency light and bell in the car 10/6/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Repair emergency light in car 12/2/2024
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Repair pit light 5/13/2021
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Cancel button in car 10/6/2023
MO Minimum : Elevators (S) - Fire Service 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) x Reinspection for fire service call cancel not working, tested and failed. Still needs to be reinspected when corrected 11/8/2023
A17.1-1996 : Elevators 3.28 - Counterweight and counterweight buffer 202 Replace rollers on counterweight frame top and bottom 1/5/2023