Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Alarm bell shall work with loss of main 120v power. 1/7/2025
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) Yes No Emergency lighting shall work. 1/7/2025
A17.1-2016: Residential 5.3.1 Private Residence Electric Elevators 5.3.1.7.2 Clearance Between Hoistway Doors and Landing Sills Yes Yes The clearance between the face of the hoistway doors and the hoistway edge of the landing sill shall not exceed 9mm (.75 inches) and 57mm (2.25 inches). Elevator Red Tagged. 5/3/2023
Missouri Minimum : Platform Lifts (U) - Existing Vertical and Inclined Platform Lifts (U)1 (Re-Inspect) Yes No Emergency light & alarm bell is not working. Re-inspection required 2/14/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes Yes For residential elevators operating in a commercial occupancy and accessible to the general public to remain in service, the owner is required to seek a variance from the Elevator Safety Board. This elevator does not have a variance. Elevator Red Tagged. 5/3/2023
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) Yes No This elevator is a residential winding drum. Category 5 testing is overdue. A category 5 test shall be performed. 5/3/2023
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No Provide a code compliant MCP including on-site documents. 10/7/2025
A17.1-1996 : Elevators 2.41 - Maintenance Records 8.6.1.4 No No A code compliant MCP and all the on-site documentation required shall be provided in the machine room. 10/7/2025
A17.1-1996 : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 10/7/2025