MO Minimum : Elevators
|
(E) - Machines
|
(E)1
|
|
|
Traction machine is making a loud noise and vibrating. Repair
|
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)1
|
|
|
Turn down fire tabs on all hoistway doors.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
Need maintenance control program on site
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current state certificate in machine room
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)1(A)
|
|
|
Ropes failed gauge test needs replacing
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Post current state certificate in machine room
|
|
MO Minimum : Elevators
|
(S) - Fire Service
|
8.6.11.1 Monthly Test and Log
|
|
|
Perform monthly fire service and document on log in machine room
|
|
MO Minimum : Elevators
|
(L) - Wire Ropes-Hoisting, Governor and Tiller
|
(L)12 (Re- Inspection)
|
x
|
|
Replace hoist ropes, red rouge reduced diameter within 30 days
|
5/13/2024
|
MO Minimum : Elevators
|
(D) - Brakes
|
(D)2
|
x
|
x
|
Test brake with 125% rated load. Did not red tag.
|
10/21/2019
|
MO Minimum : Elevators
|
(M) - Car Safeties and Speed Governors
|
(M)1
|
x
|
x
|
Test car and counterweight buggers at rated speed. Did not red tag.
|