Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform Monthly Fire service test and document on log posted in machine room Item S Rule 8.6.11.1
MO Minimum : Elevators 2.3 - Lighting and receptacles 110.27 Guarding of Live Parts NFPA 72 Install guard on the top of car light Item 2.3 Section 110.27 Guarding of live parts
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Repair Button ( pushed in ) in the car operating panel Item G Section 8.6.2.1 Repair parts
MO Minimum : Elevators (A) - Hoistways (A)2 Hoistway door panels (2 speed door) has 3/8" gap between panels. Adjust doors. 10/31/2025
MO Minimum : Elevators (A) - Hoistways (A)1 Turn down fire tabs and replace missing door gibbs on Floors 1, 3, and 4. 10/31/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need maintenance control program on site 10/31/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 10/31/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Post current state certificate in machine room 10/31/2025
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service tesing and document on log in machine room 10/31/2025