Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13 - Door systems Various floors need the fire tabs bent down
A17.1-1996 : Elevators 3.8 - Top emergency exit 1001.2(c)(12) Repair escape hatch switch that is disabled and removed from its position. 10/21/2019
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) x Emergency light inoperative. 5/1/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency alarm inoperative. 5/1/2020
A17.1-1996 : Elevators 3.23 - Suspension rope 1001.2(c)(29) x Suspension ropes are undersized. 60 day repair/reinspection. 12/21/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Door restrictor has been made inoperable. Re-inspection required 11/15/2022
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Shorten ropes 5", runby had to move finally for it to work 11/15/2022
A17.1-2016 : Elevators 5.2 - Bottom clearance, runby, and minimum refuge space 8.6.4.11 Runby (Re-Inspect) x Unit only has 4 1/4" runby and it needs 6". Top final had to be moved. Re-inspection required with in 30 days. This is the second notice 10/16/2023
A17.1-1996 : Elevators 1.18 - Restricted opening of car or hoistway doors 111.5 Restricted Opening of Hall/Car Doors x Door restrictor shall be made operable. Re-inspection required. This is the second notice 10/16/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) x Door restrictor is not working. Re-inspection required, 2nd notice 10/29/2024