Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate in the machine room
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace the burnt out pit light
MO Minimum : Elevators (I) - Pits (I)1 Clean the pit
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Replace the emergency light bulbs in the car COP
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Clean the car top and inside the car
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Replace the broken 2nd. floor car station button.
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) Replace the burnt out pit light.
MO Minimum : Elevators (I) - Pits (I)1 Clean the trash from the pit.
MO Minimum : Elevators (H) - Machine Rooms (H)4 Remove all the stored equipment from the machine room
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) Repair the machine room lights the tubes are burnt out. 2/6/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements Rotate tape reader guides as they are badly worn to one side. 2/6/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Repair the emergency alarm bell it does not work 9/4/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificte in the machine room 9/25/2019
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) x Repair or replace the emergency phone as there is no dial tone 10/21/2022