A17.1-1996 : Elevators
|
1.16 - Rated load, platform area, and data plate
|
1001.2(a)(16)
|
|
|
There is no car capacity plate inside the elevator stating the rated load of the car, as required.
|
10/20/2020
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
1001.2(b)(6)
|
|
|
The HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller.
|
10/20/2020
|
A17.1-1996 : Elevators
|
1.5 - Car lighting and receptacles
|
204.7
|
|
|
The emergency car lighting fixture is missing its protective cover. A protective cover plate shall be reinstalled for passenger safety.
|
10/20/2020
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
1001.2(b)(6)
|
|
|
The HVAC unit in the machine room shall be repaired to provide proper operation temperature for the elevator controller.
|
10/20/2020
|
A17.1-1996 : Elevators
|
2.6 - Ventilation
|
101.5b
|
|
|
A temporary air conditioning unit has been installed in the machine room. Proper code compliant permanent ventilation is required.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 - 8.6.4.13 - Door systems
|
|
|
The 4th floor is missing a pick up roller for the car door clutch to work properly. Replace missing pick up roller.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.2.1 Repair Parts
|
|
|
The position indicating or “PI” device in the car was not operational on the day of inspection. Repair “PI” device to indicate the position of the elevator car.
|
|