Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post Mo State operating certificate in machine room 3/28/2019
A17.1-2016 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No REPAIR PHONE IN THE CAR. IT DIALS OUT AND IS ANSWERED BY TK BUT THEY CANNOT HEAR THE CALLER. REINSPECTION REQUIRED WITHIN 14 DAYS.
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log No No Perform monthly fire service and document on log in machine room 5/22/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Repair phone in car 8/1/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Alarm bell not working 6/3/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No Need testing procedures included in the MCP 2/25/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Install capacity plate in car 5/22/2023
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)9 Capacity Plate No No Need capacity plate inside car 3/28/2019