Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x Ropes have been replaced but got twisted during testing. Take corrective action and re-test. Unit left shut down by maintenance company. 10/16/2024
A17.1-1996 : Elevators 3.20 - Governor rope 1001.2(c)(26) x Governor rope has grease all over it, should not be greased. Clean grease off rope. Re-inspection required 10/16/2024
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Pit needs to be cleaned
A17.1-1996 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 106.1e Illumination of Pits Pit light does not work
A17.1-1996 : Elevators 1.6 - Car emergency signal 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Emergency phone does not work. Re-inspection required 10/16/2024
A17.1-1996 : Elevators 3.23 - Suspension rope 212 x Suspension ropes have rouge and are undersized. Re-inspection required 10/16/2024