Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) Need to include testing procedures in MCP on or before January 1,2022 9/17/2021
MO Minimum : Elevators (S) - Fire Service 8.6.11.1 Monthly Test and Log Perform monthly fire service testing and document on log in machine room 10/23/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Repair/replace deflector sheave within 60 days 10/23/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) Provide testing procedures in the maintenance control program 10/23/2024
MO Minimum : Elevators (I) - Pits (I)1 Clean pit 10/23/2024
MO Minimum : Elevators (J) - Counterweights (J)3 Shackles on counterweights rubbing frame thin, need longer shackles. 12/5/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records Need maintenance control program on site posted on controller 2/12/2021
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Counterweight governor rope has to be replaced, severe rouge and multiple strands broken 1/18/2021
MO Minimum : Elevators (G)2-Alterations 8.7.2.14.2 Car Enclosure x Emergency lights in car not working 11/27/2019
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Complete annul test within 14 days unintended motion alternate fire designated floor 7/21/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts x Replace/Repair deflector sheave top of hoistway 9/18/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.2 Replacement of Suspension Means (Re-Inspection) x Replace hoist ropes (red rouge & reduced diameter) 9/18/2024
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (3) Testing Procedures (Re-Inspect) x Complete 5 yr test (Fire Service) Reinspection required 11/4/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x Test emergency generator. Reinspection required within 30 days 11/4/2024
A17.1-2016 : Elevators 1.17 - Standby power operation 8.6.4.19.7 (Re-Inspection) x test emergency generator