Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Needs OSV test with next Annual Inspection.
A17.1-2016 : Elevators 5.15 - Overspeed Valve 8.6.5.16.5 Over Speed Valve (Red Tag) x x overspeed valve sealed but not dated. needs to verify and tag or retest
A17.1-1996 : Elevators 2.6 - Ventilation 101.5b mach room A/C not working needs to be repaired room next to laundry room and does get hot
A17.1-1996 : Elevators 1.6 - Car emergency signal 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) x Phone not working 11/2/2022