A17.1-1996 : Elevators
|
3.23 - Suspension rope
|
1001.2(c)(29)
|
x
|
|
Hoist ropes need to be shortened. Counterweight less than a half inch away from buffer with car level with top floor.
|
1/6/2020
|
A17.1-1996 : Elevators
|
2.18 - Traction drive machines
|
208
|
|
x
|
Severe traction loss witnessed during testing.
|
1/6/2020
|
A17.1-1996 : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame.
|
9/29/2020
|
A17.1-1996 : Elevators
|
2.41 - Maintenance Records
|
8.6.1.4
|
|
|
MCP shall be kept in equipment room
|
9/29/2020
|