ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.14 - Code data plate
|
8.7.1.8
|
|
|
The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference.
|
10/15/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
The counterweight is missing the cotter pins to retain the counterweight at the bottom.
|
10/15/2019
|
A17.1-2016 : Elevators
|
2.40 - Maintenance Records
|
8.6.1.2.1(a)
|
|
|
Provide updated MCP
|
12/14/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Remove water from pit. Provide means to prevent accumulation of standing water
|
12/14/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)1
|
|
|
Observed mold in pit. Repair as needed
|
12/14/2021
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)6
|
|
|
Controller has incorrect car number, repair as needed
|
12/14/2021
|
A17.1-1996 : Elevators
|
3.9 - Floor and emergency identification numbering
|
1001.2(c)(15)
|
|
|
Number car top
|
12/14/2021
|
A17.1-1996 : Elevators
|
3.2 - Car top light and outlet
|
1001.2(c)(2)
|
|
|
Provide car top light to work
|
12/14/2021
|
MO Minimum : Elevators
|
(I) - Pits
|
(I)6 (Pit Lighting)
|
|
|
Light in elevator pit is not working, needs repair. Re-inspection required
|
10/14/2022
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.10 - Numbering of elevators, machines, and disconnect switches
|
2.29.1
|
|
|
COP has incorrect car number, repair as needed.
|
10/25/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.10 - Numbering of elevators, machines, and disconnect switches
|
2.29.1
|
|
|
Top of car has incorrect car number.
|
10/25/2023
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.14 - Code data plate
|
8.9
|
|
|
The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference.
|
8/29/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.28 - Counterweight and counterweight buffer
|
8.11.2.1.3(m)
|
|
|
The counterweight is missing the cotter pins to retain the counterweight at the bottom.
|
8/29/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.2-2.27.8
|
x
|
x
|
The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: In phase I operation, the car doors do not close automatically when they are in the open position. Stop operation order issued, reinspection required.
|
8/29/2019
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.6 - Car emergency signal
|
2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days)
|
x
|
|
Unable to communicate with emergency personnel over phone. Re-inspection required
|
1/15/2025
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.3 - Operating control devices
|
2.26.1.1
|
x
|
|
Fasten COP cover.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.12 - Car enclosure
|
2.14
|
x
|
|
Secure ceiling panels.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
2.14 - Code data plate
|
8.9
|
x
|
|
Put correct information on controller data tag.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
1.19 - Car Ride
|
8.11.2.1.1(s)
|
x
|
|
Correct source of grinding noise.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.7 - Car leveling and anticreep devices
|
8.11.2.1.3(j)
|
x
|
|
Car must stop level with the floor.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.8 - Top emergency exit
|
8.11.2.1.3(l)
|
x
|
|
Properly secure emergency exit.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.10 - Hoistway construction
|
8.11.2.1.3(p)
|
x
|
|
Cover large hole at top of hoistway.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.12 - Pipes, wiring, and ducts
|
8.11.2.1.3(r)
|
x
|
|
Install electrical box covers on top of car.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
3.27 - Crosshead data plate
|
8.11.2.1.3(k)
|
x
|
|
Provide crosshead data tag.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2 Design and Construction of Pits
|
x
|
|
Provide code compliant pit lighting.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.1 - Pit access, lighting, stop switch, and condition
|
2.2.2 Design and Construction of Pits
|
x
|
|
Pit shall be cleaned.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions
|
8.11.2.1.5(j)
|
x
|
x
|
Safety plank is riding on guide rails.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
5.9 - Buffers and emergency terminal speed limiting devices
|
8.10.2.2.5(c)
|
x
|
|
Install a counterweight guard in the pit.
|
8/2/2018
|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators
|
6.4 - Firefighters' service (A17.1b-1989 and later editions)
|
2.27.2-2.27.8
|
x
|
x
|
Test all phases of fire service and all initiating devices.
|