Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (H) - Machine Rooms (H)6 No No Controller has incorrect car number, repair as needed 12/14/2021
MO Minimum : Elevators (I) - Pits (I)1 No No Remove water from pit. Provide means to prevent accumulation of standing water 12/14/2021
MO Minimum : Elevators (I) - Pits (I)1 No No Observed mold in pit. Repair as needed 12/14/2021
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Light in elevator pit is not working, needs repair. Re-inspection required 10/14/2022
A17.1-1996 : Elevators 3.9 - Floor and emergency identification numbering 1001.2(c)(15) No No Number car top 12/14/2021
A17.1-1996 : Elevators 3.2 - Car top light and outlet 1001.2(c)(2) No No Provide car top light to work 12/14/2021
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.12 - Car enclosure 2.14 Yes No Secure ceiling panels. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Yes No Provide code compliant pit lighting. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.1 - Pit access, lighting, stop switch, and condition 2.2.2 Design and Construction of Pits Yes No Pit shall be cleaned. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.3 - Operating control devices 2.26.1.1 Yes No Fasten COP cover. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.6 - Car emergency signal 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Unable to communicate with emergency personnel over phone. Re-inspection required 1/15/2025
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.2-2.27.8 Yes Yes Test all phases of fire service and all initiating devices. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 6.4 - Firefighters' service (A17.1b-1989 and later editions) 2.27.2-2.27.8 Yes Yes The fireman's emergency service phase I and II operations was tested and the following deficiency was noted: In phase I operation, the car doors do not close automatically when they are in the open position. Stop operation order issued, reinspection required. 8/29/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.10 - Numbering of elevators, machines, and disconnect switches 2.29.1 No No COP has incorrect car number, repair as needed. 10/25/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.10 - Numbering of elevators, machines, and disconnect switches 2.29.1 No No Top of car has incorrect car number. 10/25/2023
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.9 - Buffers and emergency terminal speed limiting devices 8.10.2.2.5(c) Yes No Install a counterweight guard in the pit. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 1.19 - Car Ride 8.11.2.1.1(s) Yes No Correct source of grinding noise. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.7 - Car leveling and anticreep devices 8.11.2.1.3(j) Yes No Car must stop level with the floor. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.27 - Crosshead data plate 8.11.2.1.3(k) Yes No Provide crosshead data tag. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.8 - Top emergency exit 8.11.2.1.3(l) Yes No Properly secure emergency exit. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.28 - Counterweight and counterweight buffer 8.11.2.1.3(m) No No The counterweight is missing the cotter pins to retain the counterweight at the bottom. 8/29/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.28 - Counterweight and counterweight buffer 8.11.2.1.3(m) No No The counterweight is missing the cotter pins to retain the counterweight at the bottom. 10/15/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.10 - Hoistway construction 8.11.2.1.3(p) Yes No Cover large hole at top of hoistway. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 3.12 - Pipes, wiring, and ducts 8.11.2.1.3(r) Yes No Install electrical box covers on top of car. 8/2/2018
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions 8.11.2.1.5(j) Yes Yes Safety plank is riding on guide rails. 8/2/2018
A17.1-2016 : Elevators 2.40 - Maintenance Records 8.6.1.2.1(a) No No Provide updated MCP 12/14/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.2.1 Repair Parts Yes No Repair or replace T cable. Near floor the T cable is heavily gouged showing through to the copper wiring.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.11 Runby (Re-Inspection) Yes No Hoist ropes shall be shortened to increase runby measurement.
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.14 - Code data plate 8.7.1.8 No No The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference. 10/15/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.14 - Code data plate 8.9 No No The code data plate information is not is not correct. The code data plate shall list all the items that were altered and the correct code reference. 8/29/2019
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators 2.14 - Code data plate 8.9 Yes No Put correct information on controller data tag. 8/2/2018