Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
A17.1-1996 : Elevators 4.4 - Hoistway door locking devices 111 Yes No Interlock cover on the 17th floor missing. 7/27/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone shall work. 7/27/2020
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone does not work. 2/24/2021
A17.1-1996 : Elevators 1.3 - Operating control devices 1001.2(a)(3) No No Replace missing door close button tactile plate in car operating panel.
A17.1-1996 : Elevators 3.20 - Governor rope 1001.2(c)(26) Yes Yes Overspeed governor rope tension sheave is bottomed out. Shorten governor rope. Red tagged. 2/24/2021
A17.1-1996 : Elevators 1.3 - Operating control devices 1001.2(a)(3) No No Replace missing door close button tactile plate in car operating panel.
A17.1-1996 : Elevators 1.6 - Car emergency signal 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) Yes No Emergency phone does not work. 9/2/2022
A17.1-1996 : Elevators 2.7 - Fire Extinguisher 1206.1h No No Replace CO2 fire extinguishers with ABC type. Both elevator machine room and secondary spaces.
A17.1-1996 : Elevators 1.5 - Car lighting and receptacles 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) Yes No Provide existing emergency lights and bell to work.
A17.1-1996 : Elevators 1.17 - Standby power operation 1002.2g (Standby Power Operation) Yes No Provide testing of the elevator on emergency power.
A17.1-1996 : Elevators 4.12 - Standby power selection switch 1001.2(d)(12) Yes No Provide testing of the elevator emergency power selector switch (fire command room).
conversion conversion conversion - reinspect Yes No Provide Emergency Phone 3/29/2019
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.3.1 Replacement Parts No No Replace missing pull straps (3), floors 2B,S,1.. hoistway doors.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Post current State Elevator Certificate.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No Replace missing tactile plate on COP