Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.9 Cleaning of Top of Cars Car top needs cleaned
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Machine is covered in oil and needs cleaned
MO Minimum : Elevators (I) - Pits (I)1 Pit needs cleaned
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Two of the hoist ropes are crossed and one shackle has a hoist rope incorrectly seated.
MO Minimum : Elevators (L) - Wire Ropes-Hoisting, Governor and Tiller (L)12 (Re- Inspection) x Runby is 2 - Hoist ropes need shortened.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)8 Car Lighting Car lighting is hanging and needs properly fastened
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Repair Broken Flex to electrical box on crosshead
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Remove unused hanging and broken electrical cable from hoistway (can be seen from pit)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Manual Gate is missing a handle and creates a pinch hazard
MO Minimum : Elevators (I) - Pits (I)1 The elevator pit shall be kept dry. 6/3/2019
MO Minimum : Elevators (H) - Machine Rooms (H)2 Newly installed plumbing vent is vented into machine room. Either remove pipe or move machine fence to get pipe out of machine room. 11/18/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide written maintenance control program on site for each elevator. 11/18/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.5 Fire Extinguishers Fire extinguisher in the machine room is outdated. Update fire extinguisher 12/15/2021
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be clean of debris. 12/15/2021
MO Minimum : Elevators (H) - Machine Rooms (H)2 x White PVC vent pipe shall be removed from machine room, it is in front of the main line disconnect, this is the second time this has been written up. 9/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency light shall be made operational 9/1/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.1 General Maintenance Requirements Documentation Provide maintenance control programs on site for each elevator 9/8/2023
MO Minimum : Elevators (I) - Pits (I)1 Pits shall be kept clean of debris 9/8/2023
MO Minimum : Elevators (I) - Pits (I)1 Pit shall be kept clean of water and debris 9/8/2023