MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
In the machine room at the top of the hoistway, there is a small open section that creates a potential falling hazard. This open area shall be covered with approved material.
|
5/24/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
The cover for the hoistway access release chain is missing at the top floor landing. This cover shall be installed to prevent unpermitted access to the hoistway.
|
5/24/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
The drive sheave isolation pads are excessively worn and some are missing. The isolation pads shall be replaced.
|
9/16/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)4
|
|
|
The machine room shall be cleaned.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.6 General Maintenance Methods
|
|
|
Brake drum coupling needs a cotter pin or a jamb nut installed.
|
|