Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6 General Maintenance Methods Brake drum coupling needs a cotter pin or a jamb nut installed.
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x In the machine room at the top of the hoistway, there is a small open section that creates a potential falling hazard. This open area shall be covered with approved material. 5/24/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The cover for the hoistway access release chain is missing at the top floor landing. This cover shall be installed to prevent unpermitted access to the hoistway. 5/24/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The drive sheave isolation pads are excessively worn and some are missing. The isolation pads shall be replaced. 9/16/2022
MO Minimum : Elevators (H) - Machine Rooms (H)4 The machine room shall be cleaned.