Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
conversion conversion conversion - reinspect x Provide hoistway access means at top and bottom floors. 11/27/2019
conversion conversion conversion - reinspect x Install floor in overhead machine room. 11/27/2019
conversion conversion conversion - reinspect x Basement and overhead machine rooms shall have self closing and self locking doors. 11/27/2019
conversion conversion conversion - reinspect x Alarm bell shall work. 11/27/2019
conversion conversion conversion - reinspect x Guard or eliminate liquid carrying pipes in machine room. 11/27/2019
conversion conversion conversion - reinspect x Hoistway shall be enclosed. 11/27/2019
conversion conversion conversion - reinspect x Obtain and display a current state operating certificate. 11/27/2019
conversion conversion conversion - reinspect x Car lights shall be guarded. 11/27/2019
conversion conversion conversion - reinspect x Enclose hall push button wiring at floors B, 2, and 3. 11/27/2019
conversion conversion conversion - reinspect x In car stop switch shall be labeled. 11/27/2019
conversion conversion conversion - reinspect x Provide permanent stairs or ladder to overhead machine room. 11/27/2019
conversion conversion conversion - reinspect x Hoist cables shall be re-socketed every 24 months. 11/27/2019
conversion conversion conversion - reinspect x Lighting is required in overhead machine room to produce 10 ftc in all areas of the room. 11/27/2019
conversion conversion conversion - reinspect x Provide machine room fire extinguisher. 11/27/2019
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The overhead machine room door shall be self-locking and self-closing.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) A minimum of 10 fc of lighting is required in the overhead machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)1 Provide a permanent ladder or stairway to overhead machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency alarm bell shall be operational. 9/16/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The car platform toe guard shall be re-attached. 9/16/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency alarm bell is not working. 11/3/2022
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material. Cited multiple years.