Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate Obtain and display a current state operating certificate.
MO Minimum : Elevators (H) - Machine Rooms (H)2 The overhead machine room door shall be self-locking and self-closing.
MO Minimum : Elevators (H) - Machine Rooms (H)5 (Machine Room Lighting) A minimum of 10 fc of lighting is required in the overhead machine room.
MO Minimum : Elevators (H) - Machine Rooms (H)1 Provide a permanent ladder or stairway to overhead machine room.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material.
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)1 Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material. Cited multiple years.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x The in car emergency alarm bell shall be operational. 9/16/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard x The car platform toe guard shall be re-attached. 9/16/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) x Emergency alarm bell is not working. 11/3/2022
conversion conversion conversion - reinspect x Provide hoistway access means at top and bottom floors. 11/27/2019
conversion conversion conversion - reinspect x Install floor in overhead machine room. 11/27/2019
conversion conversion conversion - reinspect x Basement and overhead machine rooms shall have self closing and self locking doors. 11/27/2019
conversion conversion conversion - reinspect x Alarm bell shall work. 11/27/2019
conversion conversion conversion - reinspect x Guard or eliminate liquid carrying pipes in machine room. 11/27/2019
conversion conversion conversion - reinspect x Hoistway shall be enclosed. 11/27/2019
conversion conversion conversion - reinspect x Obtain and display a current state operating certificate. 11/27/2019
conversion conversion conversion - reinspect x Car lights shall be guarded. 11/27/2019
conversion conversion conversion - reinspect x Enclose hall push button wiring at floors B, 2, and 3. 11/27/2019
conversion conversion conversion - reinspect x In car stop switch shall be labeled. 11/27/2019
conversion conversion conversion - reinspect x Provide permanent stairs or ladder to overhead machine room. 11/27/2019
conversion conversion conversion - reinspect x Hoist cables shall be re-socketed every 24 months. 11/27/2019
conversion conversion conversion - reinspect x Lighting is required in overhead machine room to produce 10 ftc in all areas of the room. 11/27/2019
conversion conversion conversion - reinspect x Provide machine room fire extinguisher. 11/27/2019