MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
(1) Minimum Standard
|
x
|
|
The car platform toe guard shall be re-attached.
|
9/16/2022
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material.
|
|
MO Minimum : Elevators
|
(B) - Car Enclosure: Passenger
|
(B)1
|
|
|
Each passenger car shall be fully enclosed. The open sections on the side and top of the car shall be covered with approved material. Cited multiple years.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
The in car emergency alarm bell shall be operational.
|
9/16/2022
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Emergency alarm bell is not working.
|
11/3/2022
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)1
|
|
|
Provide a permanent ladder or stairway to overhead machine room.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)2
|
|
|
The overhead machine room door shall be self-locking and self-closing.
|
|
MO Minimum : Elevators
|
(H) - Machine Rooms
|
(H)5 (Machine Room Lighting)
|
|
|
A minimum of 10 fc of lighting is required in the overhead machine room.
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
|
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
Obtain and display a current state operating certificate.
|
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.4 Maintenance records
|
|
|
A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022)
|
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Provide hoistway access means at top and bottom floors.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Install floor in overhead machine room.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Basement and overhead machine rooms shall have self closing and self locking doors.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Alarm bell shall work.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Guard or eliminate liquid carrying pipes in machine room.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Hoistway shall be enclosed.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Obtain and display a current state operating certificate.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Car lights shall be guarded.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Enclose hall push button wiring at floors B, 2, and 3.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
In car stop switch shall be labeled.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Provide permanent stairs or ladder to overhead machine room.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Hoist cables shall be re-socketed every 24 months.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Lighting is required in overhead machine room to produce 10 ftc in all areas of the room.
|
11/27/2019
|
conversion
|
conversion
|
conversion - reinspect
|
x
|
|
Provide machine room fire extinguisher.
|
11/27/2019
|