Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) x The in car emergency phone shall be operational. 11/10/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.4.8 Cleaning of Machine Rooms and Machinery Spaces x Seal machine room penetrations where hydraulic pipe enters the hoistway and also above the door where conduit passes through wall. 11/10/2022
MO Minimum : Elevators (A) - Hoistways (A)13 x Seal penetrations in hoistway above top floor door where conduit passes through wall. 11/10/2022