Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators (A) - Hoistways (A)16 No No 2) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be supported as per article 620.41. Ref: 2.8.2.1 7/1/2020
MO Minimum : Elevators (A) - Hoistways (A)16 No No 3) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be ran in a raceway, 6 ft. from first point of support on the hoistway wall as per article 620.44(b). Ref: 2.8.2.1 7/1/2020
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors No No Basement level lobby flooring threshold at elevator exit causing a tripping hazard.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)10 Car Floors No No Basement level lobby flooring threshold at elevator exit causing a tripping hazard.
MO Minimum : Elevators (B) - Car Enclosure: Passenger (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) Yes No Phone failed to operate during test.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Emergency bell failed.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No 1) The following documents specified in 8.6.1.2.2(a), (b), and (c) shall be written and permanently kept on-site in the machine room, machinery space, control room, control space in hard copy for each unit for elevator personnel. (b) Procedures for inspections and tests are not on site. Ref: 8.6.1.2.2 7/1/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light failed to operate when 110 disconnected. 7/29/2024
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) Yes No Emergency light failed when 110 disconnected.
MO Minimum : Elevators (I) - Pits (I)1 No No Standing water in pit. Pit shall be kept clean and dry. 8/27/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No No current operating certificate. 4/26/2022
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests) No No Incomplete maintenance control program procedures for inspections and test are not on-site. 4/20/2022
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing 8.6.5.16.5 Over Speed Valve Testing No No OSV five (5) year test due at next inspection. 4/20/2022
conversion conversion n/a No No 1) Maintenance records shall document compliance with 8.6 of the Code and shall include records on the all activities. 7/1/2020