1) Maintenance records shall document compliance with 8.6 of the Code and shall include records on the all activities.
|
7/1/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1 Maintenance, Repair and Replacements
|
|
|
1) The following documents specified in 8.6.1.2.2(a), (b), and (c) shall be written and permanently kept on-site in the machine room, machinery space, control room, control space in hard copy for each unit for elevator personnel. (b) Procedures for inspections and tests are not on site. Ref: 8.6.1.2.2
|
7/1/2020
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
2) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be supported as per article 620.41. Ref: 2.8.2.1
|
7/1/2020
|
MO Minimum : Elevators
|
(A) - Hoistways
|
(A)16
|
|
|
3) Installation of electrical equipment and wiring shall conform to NFPA 70. Traveling cables shall be ran in a raceway, 6 ft. from first point of support on the hoistway wall as per article 620.44(b). Ref: 2.8.2.1
|
7/1/2020
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
(G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection)
|
x
|
|
Emergency light failed to operate when 110 disconnected.
|
7/29/2024
|
MO Minimum : Elevators
|
(G) - Maintenance, Repair and Replacements
|
8.6.1.2.2(b) On-Site Documentation (Procedures for Inspections and Tests)
|
|
|
Incomplete maintenance control program procedures for inspections and test are not on-site.
|
4/20/2022
|
MO Minimum : Elevators
|
CSR 40-5.100 State Operating Certificate
|
5.100(2) Display of Operating Certificate
|
|
|
No current operating certificate.
|
4/26/2022
|
MO Minimum : Elevators
|
11 CSR 40-5.090 Inspection and Testing
|
8.6.5.16.5 Over Speed Valve Testing
|
|
|
OSV five (5) year test due at next inspection.
|
4/20/2022
|