Code Item Section Reinspection Red Tag Reason For Violation Fixed Date
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No Display current state operating certificate. 8/25/2020
MO Minimum : Elevators (I) - Pits (I)6 (Pit Lighting) No No Pit light shall work. 8/25/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Shorten the hoist ropes. 8/25/2020
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 Maintenance, Repair and Replacements No No Car top light shall work. 8/25/2020
MO Minimum : Elevators (S) - Fire Service (S)1 Yes No Emergency stop switch shall be inoperable on Phase 2 fire service. 3/31/2020
MO Minimum : Elevators 11 CSR 40-5.090 Inspection and Testing (1) Minimum Standard Yes No This elevator is out of service. needs new ropes. 3/29/2021
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.4 Maintenance records No No All the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) 4/29/2021
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 12/8/2025
MO Minimum : Elevators (H) - Machine Rooms (H)2 No No Equipment in the machine room not being used in conjunction with the function or use of the elevator shall be removed. 12/8/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No The fire service phase one key switch bezel shall be legible. 12/8/2025
MO Minimum : Elevators (F) - Electrical Switches (F)8 Yes No The upper pit switch is seized in the run position and shall be repaired or replaced. 9/6/2023
MO Minimum : Elevators (F) - Electrical Switches (F)1 Yes No The in car stop key switch shall be rendered inoperative once the car is in motion while returning to the egress floor in phase one fire service. 9/6/2023
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2(d) On-Site Documentation (Written Procedures for Evacuation and Cleaning) No No Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. 12/8/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. 12/8/2025
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) Yes No Two-way communications device is not functioning and needs repair. 1/23/2025
MO Minimum : Elevators CSR 40-5.100 State Operating Certificate 5.100(2) Display of Operating Certificate No No A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.6.7 Signs and Data Plates No No The fire service phase one key switch bezel shall be legible.
MO Minimum : Elevators (G) - Maintenance, Repair and Replacements 8.6.1.2.2 On-Site Documentation No No Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site.